The SK20 uses ceramic cups made from Al203 sintered material which allows sampling and analysis for nitrate and common organic and inorganic substances.
Applications
· Continuous/discontinuous extraction
· Nitrate, chloride, sulphate, calcium, sodium, ammonium, phosphate
Benefits
· Very low dead volume
· Shaft and cup exchangeable
· pH range of 4 to 9
Limits
· Not suitable for heavy metals
Specifications
SHAFT
|
Ø 2 cm; Acrylic
|
POROUS CERAMIC
|
Ø 2 cm; length 6 cm
|
BUBBLE POINT
|
-100 kPa
|
SUCTION TUBE
|
PE; Ø 0.16 cm x Ø 0.28 cm
|
PROTECTIVE TUBE
|
PVC, Ø 1.1 cm
|
ACHIEVABLE SAMPLE AMOUNTS
|
Maximum: in free water and with a vacuum of -50 kPa approximately 5 mL per 10 minutes.
Minimum: in sandy loam soil with a vacuum of -50 kPa approximately 5 mL per hour.
|
COMPARISONS
PORE WATER SAMPLER
|
SK20/SKS20 (Internal Shaft Storage)
|
SIC20/SICS20 (Internal Shaft Storage)
|
SPE20/SPES20 (Internal Shaft Storage)
|
SUCTION CUP MATERIAL
|
Aluminum Oxide Ceramic
|
Silicon Carbide
|
Porous PE-Nylon Cup
|
CHEMICAL SUITABILITY
|
|
|
|
· Anions ( Nitrate, Sulphate, Phosphate, Chloride)
|
Suitable
|
Suitable
|
Suitable
|
· Cations (Calcium, Potassium, Sodium Ammonium)
|
Limited Suitability
|
Suitable
|
Suitable after conditioning and sufficient forerun for flushing.
|
· Metals (Aluminum, Copper, Chromium, Iron, Magnesia, Nickel)
|
Not Suitable
|
Suitable
|
Suitable
|
· Heavy Metals (Cadmium, Lead)
|
Not Suitable
|
Limited Suitability
|
Suitable
|
*See Chemical Suitability Chart for more information on chemical suitability.
|
BUBBLE POINT
|
100 kPa
|
90 kPa
|
100 kPa (PE cover only allows water flow up to 20 kPa)
|
|